DescriptionGTM96605-GEN1-T2, Medical/ITE/Household use Power Supply, Desktop/External, USB Adaptive Power, , Input Rating: 100-240V~, 50-60Hz, IEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8"), Output Rating: 60 Watts, 5, 9, 12,15, 20V in 0.1V increments, Approvals: CE PSE WEEE VCCI RoHS 2 China RoHS Level VI Double Insulation
Agency Documents
CE EC-Declaration for Medicalhttp://globtek.force.com/models/ec_declaration?id=a0O0c00000PGI8DEAX
CE EC-Declaration for Industrial/Commercial/ITEhttp://globtek.force.com/models/ec_declaration?id=a0O0c00000PGI8DEAX
RoHS/RoHS2 Declarationhttp://www.globtek.com/pdf/rohs_cert/a0O0c00000PGI8DEAX
REACH Declarationhttp://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttp://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External
TechnologyUSB Adaptive Power
CategoryMedical/ITE/Household use Power Supply
Input Voltage100-240V~, 50-60Hz
I/P Amps (A)1.5
Wattage (W)60
Vout Range (V)5, 9, 12,15, 20
EfficiencyVI
Ingress Protection
Size (mm)
EnclosureUser-added image
Rating Table
Model Number Output Voltage/Current Levels Available RFQ
GTM96605-GEN1-A1
A1 option: 5V/3A, 12V/3A, 20V/3A
RFQ
GTM96605-GEN1-A2
A2 option: 5V/4A, 12V/3.74A, 20V/2.24A
RFQ
GTM96605-GEN1-B1
B2 option: 5V/4A, 9V/4A, 15V/3A
RFQ
GTM96605-GEN1-B2
B2 option: 5V/5A, 9V/5A, 15V/3A
RFQ
SpecificationsUSB POWER DELIVERY 2.0 STANDARD, ADAPTIVE POWER OUTPUT PARAMETERS
(Note, directly compatible with USB Power Delivery 3.0 Standard)
Initial Output State, after Power-up: 5V/2A
Advertised Voltages/Currents, select one of the options from the list below:
      -A1 option: 5V/3A, 12V/3A, 20V/3A
      -A2 option: 5V/4A, 12V/3.74A, 20V/2.24A
      -B1 option: 5V/3A, 9V/3A, 15V/3A
      -B2 option: 5V/4A, 9V/4A, 15V/3A
Permanently attached, 1.5M Length, 20 Gauge with shield power cable, with 28 gauge CC1 wire terminated to Type C output connector.
A) GENERAL ELECTRICAL SPECIFICATIONS:
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
         90-264 Vac range @ 100% of rated load current    
         85-264 Vac range @ 85% of rated load current
         110-370 VDC range @ 100% of rated load current
02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
03. Output Regulation: +/- 5% measured at the output connector
04. Line Voltage Regulation: +/- 0.5% typical measured at full load
05. Green Power On Indicator LED
06. Output Ripple (Vp-p):100 mV, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with a low impedance 47 uf electrolytic capacitor connected at the end of the output connector
07. Turn-ON/OFF Overshoot: 5% maximum, 1 mS typical recovery time for 40% to 70% step load
08. Turn-ON Delay: 1 second maximum @ full load, nominal line
09. Hold-Up Time: 8 mS typical @ nominal input voltage and full load
10. Inrush Current: 30A/60A maximum cold start @ 115/230Vac input
11. Efficiency: Compliant with Efficiency Level VI and CoC Tier 2 standards
12. No Load Standby Power: <0.075 W @ 230Vac  

B) PROTECTION
01. Input Protection: Input line fusing and 300Vac MOV
02. Short Circuit/ Overload: Electronically Protected unit will auto recover upon removal of fault
        Output Current Limit: less than 110%- 130% of rated output current
03. Output Over-Voltage: 25Vdc max

C) SAFETY
01. Dielectric Withstand Voltage: 4000Vac or 5656Vdc from input to output,
On Class I models, 3000Vac or 4242Vdc from input to earth
02. Earth Leakage Current: Class I models < 300uA, N/A for Class II models
03. Touch Current: Class I models < 20uA, Class II models < 75uA
04. Output Floating or Earthed option for Class I models.
05. Earth Continuity Test: < 0.1 Ohm between Earth Pin at AC input and PCB termination point (Class I models only)
06. Means of Protection: 2 x MOPP
07. Compliant Standards: See listings at end of this drawing for specifics

D) EMC
EN 60601-1-2, 4th edition
Emissions, per EN 55032, EN 61000-6-3, EN 61000-6-4
  Conducted Emissions: Class B, FCC Part 15, Class B
  Radiated Emissions: Class B, FCC Part 15, Class B
Line Frequency Harmonics EN61000-3-2, Class A
Voltage Fluctuations/Flicker EN61000-3-3
 
Immunity, per EN 55024, EN 61000-6-1, EN 61000-6-2
  Static Discharge Immunity EN61000-4-2, 10kV Contact Discharge, 20kV air discharge
  Radiated RF Immunity EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM.
  EFT/Burst Immunity EN61000-4-4, 4kV/100kHz.
  Line Surge Immunity EN61000-4-5, 2kV differential, 4kV common-mode
  Conducted RF Immunity EN61000-4-6, 3Vrms, 80% 1KHz AM
  Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m
  Voltage Dip Immunity EN61000-4-11, Criteria

E) OTHER:
01. MTBF: 300,000 Hours @ 25°C ambient temperature
02. Operating Temperature: -10°C to 40°C ambient temperature at full load, -10°C to 50°C ambient temperature with derating to 80% load
03. Operating Humidity: 0% to 95% relative humidity, non-condensing
04. Storage Temperature: -30°C to 80°C
05. Operating Altitude: 5000 Meters
06. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006

F) ENCLOSURE
01. Housing: High impact plastic, 94V0 polycarbonate, non-vented
02. Markings: Label and/or Pad Printed and/or Molded in the case

G) SPECIAL OPTIONS
0a. Potentiometer adjusted output voltage range (hole in housing for screwdriver access)
0b. Analog Programmed output voltage adjustment, any 3 wire output cord
0c. Detachable Output Cordset
0d. Custom Markings
0e. Reduced Leakage Current versions
0f. Reduced output ripple level
0g. High Rel PCB laminate with Plated through Holes for IPC610 Class 2 Compliance
0h. Special Housing Colors and Cordset Colors
Derating CurveUser-added image
Qty (ea.)/Carton
Individual Box/Gift Box Size (mm)
Individual Box/Gift Box Color
Master Carton Size (mm)TBD
Gross Weight (kg)
Label Width (mm)
Label Height (mm)
Input Configuration
DescriptionIEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8")User-added image

Mates with IEC 60320/C7 Plug

Standard International IEC 320/C7 Cordsets

Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Please contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.
 

2 Conductors (No Ground) IEC 320/C7 (Figure "8")

4511116F703A(R)

N. American

NEMA 1-15P

IEC 320/C7

1830

6

5014112M703A(R)

Australian

AS 3112

IEC 320/C7

2000

7

4533501M8703(R)

China

GB 2099.1

IEC 320/C7

1830

6

2074112M703A(R)

European

CEE 7/16

IEC 320/C7

2000

7

451J3401M8703(R)

Japan

JIS 8303

IEC 320/C7

1830

6

6104112M703A(R)

UK

BS1363

IEC 320/C7

2000

7

Output Configuration
Common output connector options:
Click to add to your request.






L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector






YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) USBC Type (USB Type C) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
User-added image  CE Certification
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
User-added image

Double Insulation - Mark is on the label or Molded in the case
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
User-added imageJAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: http://en.globtek.com/importing-to-japan.php.
RoHS 2RoHS 2: Complies with EU 2011/65/EU and CHINA SJ/T 11363-2006 http://www.ce-mark.com/Rohs%20final.pdf
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case

Bilgi İste